Media 000354515: Otic Capsule/Partial Basicranium
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000354515
Media type
Volumetric Image Series
Object element or part
otic capsule/partial basicranium
Object represented
Object taxonomy
Meiolania platyceps
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 01, 2021

FILE OBJECT DETAILS Field Definitions

File name
Meiolania_platyceps_NHMUKR682_leftotic.zip
File format(s)
ZIP archive, TIFF
File size
1.15 GB
Image width
1555
Image height
1916
Color space
BlackIsZero
Color depth
8
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.084978
Y pixel spacing
0.084978
Z pixel spacing
0.084978
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,433

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Natural History Museum London (NHMUK)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to Serjoscha Evers on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NHMUK:PAL:PV R 682 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Evers, Serjoscha
Event date
September 29, 2016
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1000 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
200 kV
Power
--
Amperage
255 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000354515: Otic Capsule/Partial Basicranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Evers, Serjoscha
Event date
September 29, 2016
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000354515: Otic Capsule/Partial Basicranium [CTImageSeries] [CT] (this media)