Media 000358040: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

GENERAL DETAILS Field Definitions

Media ID
000358040
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Protoceras celer
Side
NotApplicable
Orientation
--
Short description
High-resolution scan of basicranium
Full description
--
Creator
--
Date created
--
Date uploaded
April 15, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
433 MB
Image width
1024
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.074360
Y pixel spacing
0.074360
Z pixel spacing
0.074360
Pixel spacing units
Mm
Slice thickness
0.07436
Number of images in set
300

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:fm:53523 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matt Colbert
Event date
May 22, 2007
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
210 kV
Power
--
Amperage
0.11 mA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000358040: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Alison Mote
Event date
May 22, 2007
Software
--
Description
Ring-removal
Description attachment
None

Processing Activity 1: Smoothing/Noise Reduction

Software
Description

Processing Activity 2: Reconstruction

Software
Description

Media produced by this event on MorphoSource

Media 000358040: Skull [CTImageSeries] [CT] (this media)