Media 000359364: Head Ct
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000359364: Head Ct
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000359364
Media type
Volumetric Image Series
Object element or part
head CT
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
--
Orientation
Axial
Short description
Data is the head of a 72 year old male donor. The donor was preserved in formalin and the blood vessels were filled with araldite-F.
Full description
Brigham and Women's Hospital
Havard Medical School
Dr. Peter Ratiu
ratiu@bwh.havard.edu
Data is the head of a 72 year old male donor. The donor was
preserved in formalin and the blood vessels were filled with
araldite-F. Before freezing, MRI and CAT imaging was preformed.
After freezing the specimen was cryo sectioned at 0.147mm intervals
and digital photographs were taken with a resolution of
1056 x 1528 pixels.
For a complete description of the procedure see:
P. Ratiu, B. Hillen, J. Glase and D.P. Jenkins.
'Visible Human 2.0 - The Next Generation'
"Medicine Meets Virtual Reality 11 - NextMed: Health Horizon"
edited by J.D. Westwood et al. IOS Press, 2003. pp 275-281.
This work was performed under contract LM-1-3535
"The Visible Human Project Anatomical Methods"
Creator
--
Date created
--
Date uploaded
April 21, 2021
FILE OBJECT DETAILS Field Definitions
File name
Visible_Human_2_head_ct.zip
File format(s)
ZIP archive, DICOM
File size
105 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.489062
Y pixel spacing
0.489062
Z pixel spacing
0.503247
Pixel spacing units
Mm
Slice thickness
1.500000
Number of images in set
463
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Philips Tomoscan AVEU, University Medical Center Utrecht (University Medical Center Utrecht)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
National Library of Medicine (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nlm:NLM:2
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
University Medical Center Utrecht (University Medical Center Utrecht)
Creator
--
Event date
April 05, 2002
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000359364: Head Ct [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
April 21, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000359364: Head Ct [CTImageSeries] [CT] (this media)