Media 000364410: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000364410: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000364410
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Gerrhosaurus flavigularis
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 20, 2021
FILE OBJECT DETAILS Field Definitions
File name
UF-H-63112-BODY.zip
File format(s)
ZIP archive, application/octet-stream
File size
2.67 GB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.076605
Y pixel spacing
0.076605
Z pixel spacing
0.076605
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,192
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:63112
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray and Edward Stanley
Event date
--
Software
Datos X|A
Description
microCT of UF-herp-63112
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
960
Voltage
100KV
Power
20W
Amperage
200uA
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000364410: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Edward Stanley
Event date
May 19, 2021
Software
Datos X|R
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000364410: Whole Body [CTImageSeries] [CT] (this media)