Media 000366658: Sacrum
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000366658: Sacrum
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000366658
Media type
Volumetric Image Series
Object element or part
sacrum
Object represented
Object taxonomy
Pan troglodytes troglodytes
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - sacrum
Full description
University of Texas High-Resolution X-ray CT Facility Archive 2790
Russo:
gontro: Scans of two sacra: Gorilla gorilla gorilla (AMNH 167339; female, Cameroon) at top of field of view; and Pan troglodytes (AMNH 167343; female, Cameroon) at bottom of field of view, for Gabrielle Russo of UT Anthropology. Specimens scanned by Matthew Colbert 14 August 2012.
16bitrot: 1024x1024 16-bit TIFF images. II, 200 kV, 0.24 mA, intensity control off, high-power mode, no filter, empty container wedge, no offset, slice thickness 1 line ( = 0.08015 mm), S.O.D. 230 mm, 1800 views, 2 samples per view, inter-slice spacing 1 line ( = 0.08015 mm), field of reconstruction 76.5 mm (maximum field of view 76.51212 mm), reconstruction offset 4000, reconstruction scale 5000. Acquired with 31 slices per rotation and 25 slices per set. Ring-removal processing done by Julia Holland based on correction of raw sinogram using IDL routine “RK_SinoRingProcSimul” with parameter “bestof5=11, binwidth=5.” Reconstructed with beam-hardening coefficients [0, 0.85, 0.05], and rotation = 0.2° CW, X offset = 0.15, and Y offset = 0.07 (slices 156 – 2201). Deleted first 3 and last 3 duplicate slices from each rotation. Rotation correction processing done by Julia Holland using IDL routine “DoRotationCorrection.” Deleted first 20 and last 20 blank slices. Total final slices = 1735.
Creator
Matthew Colbert
Date created
August 14, 2012
Date uploaded
June 04, 2021
FILE OBJECT DETAILS Field Definitions
File name
AMNH_167343.zip
File format(s)
ZIP archive, TIFF
File size
3.61 GB
Image width
1023
Image height
755
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.074710
Y pixel spacing
0.074710
Z pixel spacing
0.080150
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,735
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, BCS-1156016
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant BCS-1156016 to Gabrielle Russo. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Mammals:M-167343
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000366658: Sacrum [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
June 04, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000366658: Sacrum [CTImageSeries] [CT] (this media)