Media 000367822: Element Unspecified
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000367822: Element Unspecified
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000367822
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Tomistoma schlegelii
Object organization
Side
--
Orientation
--
Short description
Neurovascular canals in the rostrum of Tomistoma schlegelii (TMM M-6342)
Full description
Segmented neurovascular canals in the rostrum of a subadult Tomistoma schlegelii (TMM M-6342). These canals would have transferred neurovasculature to the surface of the snout.
Creator
--
Date created
June 15, 2021
Date uploaded
June 15, 2021
FILE OBJECT DETAILS Field Definitions
File name
Tomistoma_schlegelii_TMM_M-6342_cIS.ply
File format(s)
PLY
File size
3.08 MB
Points
73784
Polygons
146724
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
67.655, 208.842, 23.596
Centroid coordinates
80.696, 161.615, 87.430
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmm:m:6342
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
420
Power
--
Amperage
1800
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114920: Skull [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000114920: Skull [CTImageSeries] [Etc]
was processed
to create
derived
Media 000367822: Element Unspecified [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
June 15, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000367822: Element Unspecified [Mesh] [CT] (this media)