Media 000367822: Element Unspecified
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000367822
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Tomistoma schlegelii
Side
--
Orientation
--
Short description
Neurovascular canals in the rostrum of Tomistoma schlegelii (TMM M-6342)
Full description
Segmented neurovascular canals in the rostrum of a subadult Tomistoma schlegelii (TMM M-6342). These canals would have transferred neurovasculature to the surface of the snout.
Creator
--
Date created
June 15, 2021
Date uploaded
June 15, 2021

FILE OBJECT DETAILS Field Definitions

File name
Tomistoma_schlegelii_TMM_M-6342_cIS.ply
File format(s)
PLY
File size
3.08 MB
Points
73784
Polygons
146724
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
67.655, 208.842, 23.596
Centroid coordinates
80.696, 161.615, 87.430
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:6342 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
420
Power
--
Amperage
1800
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114920: Skull [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000114920: Skull [CTImageSeries] [Etc] was processed to create derived Media 000367822: Element Unspecified [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
June 15, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000367822: Element Unspecified [Mesh] [CT] (this media)