Media 000368673: Mandible
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000368673
Media type
Volumetric Image Series
Object element or part
mandible
Object represented
Object taxonomy
Saimiri sciureus sciureus
Object organization
Side
--
Orientation
--
Short description
HRXCT - mandible
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0800 Ryan: saiCE: Scans of the mandibles of Saimiri sciureus (USNM 518543; male; Brazil, Amazonas, Sao Paulo de Olivenca, Varzea, Paranamirim do Municipio; coll. 20 August 1948) and Saimiri sciureus (USNM 518541; male; Brazil, Amazonas, Codajaz, Mata do Engenho; coll. 24 May 1948) for Timothy Ryan of the Duke University Primate Center. Scanned by Richard Ketcham 13 January 2003. USNM 518543 is on the left of the image, 518541 is on the right (teeth end first). 16bit: 1024x1024 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, air wedge, no offset, slice thickness = 1 line (= 0.0230 mm), S.O.D. 67 mm, 1000 views, 2 samples per view, interslice spacing = 1 line (=0.0230 mm), field of reconstruction 21.8 mm (maximum field of view = 21.93), reconstruction offset 6000, reconstruction scale 900. Acquired with 25 slices per rotation. Total slices = 1675.
Creator
Richard Ketcham
Date created
January 31, 2003
Date uploaded
June 19, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
982 MB
Image width
474
Image height
896
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.021300
Y pixel spacing
0.021300
Z pixel spacing
0.023000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,675

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by Tim Ryan. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:MAMM:USNM 518541 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000368673: Mandible [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000368673: Mandible [CTImageSeries] [CT] (this media)