Media 000369408: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

TAGS

GENERAL DETAILS Field Definitions

Media ID
000369408
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Gekko gecko
Side
NotApplicable
Orientation
--
Short description
DICECT scan of whole body
Full description
--
Creator
Edward Stanley
Date created
--
Date uploaded
July 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
uf-herp-72672-dicect-body.zip
File format(s)
ZIP archive
File size
5.41 GB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.032676
Y pixel spacing
0.032676
Z pixel spacing
0.032676
Pixel spacing units
Mm
Slice thickness
0.0326758

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:72672 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley and Jaimi Gray
Event date
--
Software
Datos X|a
Description
DICECT scan of UF-Herp-72672
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2000
Voltage
160
Power
28.8
Amperage
180
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000369408: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
Datos X|R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000369408: Whole Body [CTImageSeries] [CT] (this media)