Media 000369759: Cranial Elements
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000369759: Cranial Elements
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000369759
Media type
Volumetric Image Series
Object element or part
cranial elements
Object represented
Object taxonomy
Alphadon halleyi
Object organization
Side
NotApplicable
Orientation
--
Short description
Block containing one braincase specimen yielded an associated right maxilla and isolated teeth (Freimuth et al. 2021, fig. s1). Has been converted from 32bit to 16bit.
Full description
--
Creator
Julie Winchester
Date created
July 09, 2021
Date uploaded
July 09, 2021
FILE OBJECT DETAILS Field Definitions
File name
Alphadon-skull-dinner_7-12-12-9-Y-Slices-16-bit.zip
File format(s)
ZIP archive, TIFF
File size
2.81 GB
Image width
1425
Image height
1076
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.024400
Y pixel spacing
0.024400
Z pixel spacing
0.024400
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,307
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(2 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, X-ray Computed Tomography Facility (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Montana State University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mor:MOR 10913a
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
X-ray Computed Tomography Facility (University of Washington)
Creator
Bannick, Alexandria
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000369549: Cranial Elements [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000369549: Cranial Elements [CTImageSeries] [CT]
was processed
with 2 activities
to create
derived
Media 000369759: Cranial Elements [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Julie Winchester
Event date
July 09, 2021
Software
Fiji ImageJ
Description
--
Description attachment
None
Processing Activity 1: Bit Depth Change
Software
Fiji ImageJ
Description
Changed from 32 bit to 16 bit.
Processing Activity 2: Histogram Editing
Software
Fiji ImageJ
Description
After bit depth change, stack appeared washed out (too many white pixels). Reset the brightness/contrast histogram, and applied the reset LUT to all stack images.
Media produced by this event on MorphoSource
Media 000369759: Cranial Elements [CTImageSeries] [CT] (this media)