Media 000372585: Proothic
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000372585
Media type
Mesh
Object element or part
Proothic
Object represented
Object taxonomy
Neusticemys neuquina
Side
NotApplicable
Orientation
--
Short description
Proothic
Full description
Proothic bones of the N. neuquina juvenile
Creator
--
Date created
July 27, 2021
Date uploaded
July 27, 2021

FILE OBJECT DETAILS Field Definitions

File name
Proothic.stl
File format(s)
STL
File size
516 KB
Points
5494
Polygons
10568
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
25.062, 9.526, 13.142
Centroid coordinates
0.596, -4.829, -48.665
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner, Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object na was imaged to create raw Media 000372286: Element Unspecified [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
Creator
Pablo González Ruiz; Marcelo de la Fuente
Event date
June 07, 2019
Software
3D Slicer
Description
--
Description attachment
None
Reference attachment
None
Exposure time
9 minutes
Flux normalization
Yes
Pixel spacing calibration
Fiducial
Shading correction
Yes
Frame averaging
--
Projections
--
Voltage
139kV
Power
--
Amperage
140µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
Yes
Optical magnification
No
Acquisition type
Stationary

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000372286: Element Unspecified [CTImageSeries] [CT] was processed to create derived Media 000372585: Proothic [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
3D Slicer
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000372585: Proothic [Mesh] [CT] (this media)