Media 000373611: Left Laterosphenoid
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000373611
Media type
Mesh
Object element or part
left laterosphenoid
Object represented
Object taxonomy
Irritator challengeri
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Schade, Marco
Date created
--
Date uploaded
August 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
laterosphenoid_left.ply
File format(s)
PLY
File size
70 MB
Points
966206
Polygons
1932384
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
62.330, 52.112, 52.062
Centroid coordinates
214.881, 143.020, 214.635
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Metrotom 1500, Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
SMNS Stuttgart (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Marco Schade provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smns:58022 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
180
Power
--
Amperage
1800
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000101461: Braincase [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000101461: Braincase [CTImageSeries] [Etc] was processed with 1 activity to create derived Media 000373611: Left Laterosphenoid [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Schade, Marco
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
amira
Description

Media produced by this event on MorphoSource

Media 000373611: Left Laterosphenoid [Mesh] [CT] (this media)