Media 000374483: Reconstructed Cranium
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000374483: Reconstructed Cranium
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000374483
Media type
Mesh
Object element or part
Reconstructed cranium
Object represented
Object taxonomy
Annemys sp.
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
--
Date uploaded
August 04, 2021
FILE OBJECT DETAILS Field Definitions
File name
Annemys_IVPP_V18106_Cranium_reconstructed.ply
File format(s)
PLY
File size
119 MB
Points
3525287
Polygons
1175097
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
40414.199, 55050.699, 19067.770
Centroid coordinates
34.121, 22.030, -235.356
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ivpp:v:18106
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000374483: Reconstructed Cranium [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Serjoscha Evers
Event date
--
Software
Blender; Mimics
Description
In Annemys sp. (IVPP V18106), the skull roof is broken off the rest of the cranium, and both parts are separated by a large fracture line (see also Brinkman et al. 2013). We segmented both parts separately in Mimics, and re-articulated the skull roof to the rest of the skull in Blender.
Description attachment
None
Media produced by this event on MorphoSource
Media 000374483: Reconstructed Cranium [Mesh] [CT] (this media)