Media 000378336: Brain/Ear Endocast
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000378336
Media type
Mesh
Object element or part
Brain/Ear Endocast
Object represented
Object taxonomy
Catharus guttatus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Ryan Ridgely
Date created
August 17, 2021
Date uploaded
August 17, 2021

FILE OBJECT DETAILS Field Definitions

File name
Catharus_guttatus_USNM_634096.stl
File format(s)
STL
File size
47.8 MB
Points
489084
Polygons
980080
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
14.168, 12.182, 12.931
Centroid coordinates
0.107, 8.905, -8.169
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo, Ohio University MicroCT Facility (Ohio University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
US National Science Foundation grants to L. M. Witmer & R. C. Ridgely: NSF IBN-0343744, IOB-0517257, IOS-1050154, and IOS-1456503
Publisher
--
Cite as
--
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:BIRDS:USNM 634096 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
400
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
4
Projections
1200
Voltage
80
Power
--
Amperage
450
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000377997: Skull Ct Data [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000377997: Skull Ct Data [CTImageSeries] [CT] was processed to create derived Media 000378336: Brain/Ear Endocast [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Ryan Ridgely
Event date
--
Software
Amira
Description
Endocast
Description attachment
None

Media produced by this event on MorphoSource

Media 000378336: Brain/Ear Endocast [Mesh] [CT] (this media)