Media 000381781: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000381781
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Protoblepharus apatani
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Gorin, Vladislav A.
Date created
May 13, 2021
Date uploaded
September 03, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
311 MB
Image width
2746
Image height
328
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.009000
Y pixel spacing
0.009000
Z pixel spacing
0.009000
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,054

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker Skyscan 1172, Moscow State University Geology Department (M.V. Lomonosov Moscow State University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object BNHS:Herp:2853 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Moscow State University Geology Department (M.V. Lomonosov Moscow State University)
Creator
Gorin, Vladislav A.
Event date
May 13, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1791
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
720
Voltage
50
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000381781: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Gorin, Vladislav A.
Event date
May 13, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000381781: Head [CTImageSeries] [CT] (this media)