Media 000382702: Cranial Endocast
Restricted Download
Type Mesh
Modality Synchrotron Imaging
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000382702
Media type
Mesh
Object element or part
Cranial endocast
Object represented
Object taxonomy
Rhinodipterus ulrichi
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Tom Challands
Date created
September 12, 2021
Date uploaded
September 12, 2021

FILE OBJECT DETAILS Field Definitions

File name
Rhino-ulrichi_Endocast_001.stl
File format(s)
STL
File size
13.4 MB
Points
140802
Polygons
281837
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.341, 13.313, 5.155
Centroid coordinates
3.865, 10.964, 5.152
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
Synchrotron Imaging
Device
ESRF Beamline ID19, European Synchrotron Radiation Facility (European Synchrotron Radiation Facility)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
This work was supported by a Wallenberg Foundation grant to Per Erik Ahlberg (Uppsala University).
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object esrf:P6609a was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
Synchrotron Imaging
Device facility
European Synchrotron Radiation Facility (European Synchrotron Radiation Facility)
Creator
Paul Tafforeau
Event date
--
Software
--
Description
Rhinodipterus ulrichi was scanned at the European Synchrotron Radiation Facility (ESRF) on beamline ID19 using propagation phase-contrast X-ray synchrotron radiation micro-computed tomography (PPC-SRµCT) and the attenuation protocol of Sanchez et al. (2013) with 4 meters between the sample and detector. It was imaged with 90 keV, with 4000 projections over 360 degrees of 0.1 second each, in half-acquisition mode. Two columns of 30 scans each were required to capture the entire specimen, which had a resultant voxel size of 30 µm.
Description attachment
None
Reference attachment
None

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000382063: Nodule Containing Head And Anterior Elements [CTImageSeries] [Synchro].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

STEP 3: IMAGE PROCESSING

Derived Media 000382063: Nodule Containing Head And Anterior Elements [CTImageSeries] [Synchro] was processed to create derived Media 000382702: Cranial Endocast [Mesh] [Synchro] (this media).

Processing Details Field Definitions

Creator
Tom Challands
Event date
--
Software
Drishti Paint
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000382702: Cranial Endocast [Mesh] [Synchro] (this media)