Media 000383562: Femur
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000383562: Femur
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000383562
Media type
Mesh
Object element or part
Femur
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
Right
Orientation
--
Short description
Hollowed PLY
Full description
Hollowed PLY with ambient occlusion shading. Can be used as is or converted to STL for 3D printing.
Creator
Simmons-Ehrhardt, Terrie
Date created
September 16, 2021
Date uploaded
September 16, 2021
FILE OBJECT DETAILS Field Definitions
File name
AFIP_1000243_Sketchfab.ply
File format(s)
PLY
File size
36.4 MB
Points
707507
Polygons
1415266
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
93.684, 59.558, 277.775
Centroid coordinates
54.895, 39.509, 160.086
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nmhm:cw:AFIP-1000243
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
July 17, 2019
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
18m45s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
4
Projections
500
Voltage
160
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
974.166
Source detector distance
1237.269
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000383559: Femur [Mesh] [CT].
Processing Details Field Definitions
Creator
Brian Spatola
Event date
June 01, 2020
Software
Mimics
Description
PLY model generated with Mimics, ambient occlusion shading applied with Meshlab.
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000383559: Femur [Mesh] [CT]
was processed
to create
derived
Media 000383562: Femur [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Simmons-Ehrhardt, Terrie
Event date
September 16, 2021
Software
Meshlab
Description
Hollowed version of hi-res PLY, with internal structures removed. Can be used as is or converted to STL for 3D printing.
Description attachment
None