Media 000383617: Radius/Ulna
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000383617
Media type
Mesh
Object element or part
Radius/Ulna
Object represented
Object taxonomy
Homo sapiens
Side
Right
Orientation
--
Short description
PLY model
Full description
PLY model generated in Mimics, ambient occlusion shading applied in Meshlab.
Creator
Brian Spatola
Date created
June 01, 2020
Date uploaded
September 17, 2021

FILE OBJECT DETAILS Field Definitions

File name
AFIP_1000642_ao.ply
File format(s)
PLY
File size
71.6 MB
Points
1378161
Polygons
2803939
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
61.241, 90.864, 222.696
Centroid coordinates
37.432, 45.869, 114.516
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nmhm:cw:AFIP-1000642 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
July 31, 2018
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
20m49s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1000
Voltage
200
Power
--
Amperage
600
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
797.318
Source detector distance
1295.558
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000383617: Radius/Ulna [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Brian Spatola
Event date
June 01, 2020
Software
Mimics
Description
PLY model generated in Mimics, ambient occlusion shading applied in Meshlab.
Description attachment
None

Media produced by this event on MorphoSource

Media 000383617: Radius/Ulna [Mesh] [CT] (this media)