Media 000385239: Cranium
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000385239: Cranium
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000385239
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Gorilla gorilla gorilla
Object organization
Side
--
Orientation
--
Short description
87.72µm µCT scan of the cranium of AGH_05
Full description
--
Creator
Renaud Lebrun
Date created
January 22, 2020
Date uploaded
September 27, 2021
FILE OBJECT DETAILS Field Definitions
File name
SlicesY.zip
File format(s)
ZIP archive, TIFF
File size
7.46 GB
Image width
1584
Image height
1469
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.087719
Y pixel spacing
0.087719
Z pixel spacing
0.087719
Pixel spacing units
Mm
Slice thickness
0.0877185
Number of images in set
2,380
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
RX Solutions EasyTom 150, Montpellier Resources Imagerie: Institut des Sciences de l’Evolution de Montpellier (MRI-ISEM) (Université de Montpellier)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
isem:AGH_05
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Montpellier Resources Imagerie: Institut des Sciences de l’Evolution de Montpellier (MRI-ISEM) (Université de Montpellier)
Creator
Renaud Lebrun
Event date
January 22, 2020
Software
XAct
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
8
Projections
1440
Voltage
110 kV
Power
0.046 kW
Amperage
421 µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
Scintillator (Phosphor used)
Detector pixels X
1920
Detector pixels size X
127
Detector pixels Y
1536
Detector pixels size Y
127
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
5
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000385239: Cranium [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Renaud Lebrun
Event date
January 22, 2020
Software
XAct
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000385239: Cranium [CTImageSeries] [CT] (this media)