Media 000393268: Full Body Mesh
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000393268: Full Body Mesh
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000393268
Media type
Mesh
Object element or part
full body mesh
Object represented
Object taxonomy
Peromyscus melanotis
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Shion Otsuka
Date created
October 29, 2021
Date uploaded
October 29, 2021
FILE OBJECT DETAILS Field Definitions
File name
full_body.stl
File format(s)
STL
File size
42.6 MB
Points
437424
Polygons
890065
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.543, 42.098, 82.475
Centroid coordinates
4.211, -1.174, 15.971
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
University of Michigan, Museum of Zoology, 3600 Varsity Drive, Ann Arbor, Michigan 48108
Cite as
If the Digital Data were produced by the UMMZ, you agree that the attribution, in an acknowledgements section or similar will read:
“The data was provided courtesy of the University of Michigan Museum of Zoology.”
If the Digital Data represent a voucher specimen held by the UMMZ, the catalog number of the specimen must be referenced in the Specimen Examined or similar section in the manuscript (e.g., ummz:mammals:12345).
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UMMZ:mammals:112996
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
Creator
Ramon Nagesan, Gregory Pandelis
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
250
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1601
Voltage
85
Power
0.017
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000076465: Whole Body [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Ramon Nagesan, Gregory Pandelis
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000076465: Whole Body [CTImageSeries] [Etc]
was processed
to create
derived
Media 000393268: Full Body Mesh [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Shion Otsuka
Event date
--
Software
VGSTUDIO MAX 3.3
Description
full body mesh
Description attachment
None
Media produced by this event on MorphoSource
Media 000393268: Full Body Mesh [Mesh] [CT] (this media)