Media 000394408: Distal Femur
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000394408
Media type
Volumetric Image Series
Object element or part
Distal Femur
Object represented
Object taxonomy
Homo sapiens
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Terrie Simmons-Ehrhardt
Date created
November 04, 2021
Date uploaded
November 04, 2021

FILE OBJECT DETAILS Field Definitions

File name
afip0385009_8bitunsignedchar.zip
File format(s)
ZIP archive, DICOM
File size
585 MB
Image width
804
Image height
713
Color space
--
Color depth
8
Compression
--
X pixel spacing
0.118400
Y pixel spacing
0.118400
Z pixel spacing
0.118400
Pixel spacing units
Mm
Slice thickness
0.1184
Number of images in set
1,694

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nmhm:cw:AFIP-0385009 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
June 25, 2018
Software
--
Description
8 bit dicoms
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
28m47s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
4
Projections
1000
Voltage
150
Power
--
Amperage
225
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
660.516
Source detector distance
1094.469
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000394408: Distal Femur [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Terrie Simmons-Ehrhardt
Event date
November 04, 2021
Software
3D Slicer
Description
8 bit dicoms exported from nrrd volume
Description attachment
None

Media produced by this event on MorphoSource

Media 000394408: Distal Femur [CTImageSeries] [CT] (this media)