Media 000396185: Element Unspecified
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000396185: Element Unspecified
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000396185
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Apis mellifera
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
November 16, 2021
Date uploaded
November 16, 2021
FILE OBJECT DETAILS Field Definitions
File name
60185_AM_surfaces_LabelsForMatlab.zip
File format(s)
ZIP archive, TIFF
File size
617 KB
Image width
294
Image height
543
Color space
BlackIsZero
Color depth
8
Compression
LZW
X pixel spacing
5.000000
Y pixel spacing
5.000000
Z pixel spacing
5.000000
Pixel spacing units
--
Slice thickness
--
Number of images in set
177
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Diamond Manchester Imaging Branchline (I13-2), I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
lu:bvg:3_14-AM_F_5
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000396182: Scan 60185 [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000396182: Scan 60185 [CTImageSeries] [CT]
was processed
to create
derived
Media 000396185: Element Unspecified [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
Label
Description attachment
None
Media produced by this event on MorphoSource
Media 000396185: Element Unspecified [CTImageSeries] [CT] (this media)