Media 000404925: Scapula
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000404925
Media type
Mesh
Object element or part
Scapula
Object represented
Object taxonomy
Ichthyornis sp.
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Field, Daniel; Benito, Juan
Date created
--
Date uploaded
December 06, 2021

FILE OBJECT DETAILS Field Definitions

File name
FHSM_18702_-_Scapula_left.stl
File format(s)
STL
File size
2.79 MB
Points
29067
Polygons
58258
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.971, 9.432, 58.602
Centroid coordinates
5.682, -6.311, -12.579
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FHSM:vp:18702 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
FHSM VP-18702 (block containing scapula, tibiotarsus and tarsometatarsus): NSI scanner at UTCT. Feinfocus source, high power, 170 kV, 0.180 mA, 1 aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 282.463 mm, source to detector 1316.685 mm, continuous CT scan, 2 frames averaged, 0 skip frames, 2460 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-0.3, 4.6] (grayscale range adjusted from NSI defaults), beam-hardening correction = 0.05. Voxel size = 0.0447 mm. Total slices = 1767.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000404925: Scapula [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Field, Daniel, Benito, Juan
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000404925: Scapula [Mesh] [CT] (this media)