Media 000409033: Dentary Ramus
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000409033: Dentary Ramus
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000409033
Media type
Mesh
Object element or part
Dentary ramus
Object represented
Object taxonomy
Dermatemys mawii
Object organization
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
December 21, 2021
Date uploaded
December 21, 2021
FILE OBJECT DETAILS Field Definitions
File name
Dermatemys_mawii_CM-herps-117802_L_dentary_ramus.ply
File format(s)
PLY
File size
5.75 MB
Points
136421
Polygons
274674
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
21.750, 36.722, 14.469
Centroid coordinates
40.639, 24.440, 8.965
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
CM:Herps:117802
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1200
Voltage
120
Power
--
Amperage
200
Surrounding material
empty mount
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114482: Skull [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000114482: Skull [CTImageSeries] [Etc]
was processed
to create
derived
Media 000409033: Dentary Ramus [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Serjoscha Evers
Event date
--
Software
Mimics
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000409033: Dentary Ramus [Mesh] [CT] (this media)