Media 000417917: Whole Specimen
Open Download
Type
Image
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000417917: Whole Specimen
Open Download
Type
Image
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview disabled by data contributor.
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000417917
Media type
Image
Object element or part
Whole specimen
Object represented
Object taxonomy
Diospyrocarpum senescens
Object organization
Side
NotApplicable
Orientation
--
Short description
Volume render of dataset F10
Full description
Volume render of dataset F10 using Drishti.
Creator
Alan Spencer
Date created
January 30, 2022
Date uploaded
January 30, 2022
FILE OBJECT DETAILS Field Definitions
File name
image_1_edited.png
File format(s)
PNG
File size
1.16 MB
Image width
1047
Image height
1022
Color space
--
Color depth
--
Compression
Deflate; Deflate/Inflate
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Thumbnail Only
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mhnan:2011-pb:208
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Alan Spencer
Event date
February 03, 2015
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
708.00 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3142
Voltage
210
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
Transmission
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000417914: Whole Specimen [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Alan Spencer
Event date
April 04, 2018
Software
--
Description
Subset of larger CT dataset, derived for VOL file data, cut down to only show the specimen.
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000417914: Whole Specimen [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000417917: Whole Specimen [Image] [CT] (this media).
Processing Details Field Definitions
Creator
Alan Spencer
Event date
--
Software
--
Description
Volume rendered image of dataset using Drishti.
Description attachment
None
Processing Activity 1:
Software
Drishti
Description
Media produced by this event on MorphoSource
Media 000417917: Whole Specimen [Image] [CT] (this media)