Media 000418324: Pelvis
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000418324
Media type
Mesh
Object element or part
Pelvis
Object taxonomy
Ramphotyphlops braminus
Side
--
Orientation
--
Short description
--
Full description
--
Creator
S. Swank
Date created
January 07, 2021
Date uploaded
January 31, 2022

FILE OBJECT DETAILS Field Definitions

File name
Ib.53250.ugly.182.clean.ply
File format(s)
PLY
File size
25.3 MB
Points
1844257
Polygons
339527
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
17.565, 11.891, 9.667
Centroid coordinates
9.365, -4.999, 5.420
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Perkin Elmer Quantum GX2, LUC Department of Biology (Loyola University Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DEB-1456462
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
LUC Department of Biology (Loyola University Chicago)
Creator
S. Swank
Event date
January 07, 2021
Software
InVesalius 3.1; MeshLab 2020.12
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4 min
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65-70 kV
Power
--
Amperage
100-114 mA
Surrounding material
Plastic bag
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000418321: Pelvis [CTImageSeries] [CT] was processed with 2 activities to create derived Media 000418324: Pelvis [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
S. Swank
Event date
January 07, 2021
Software
MeshLab 2020.12; InVesalius 3.1
Description
--
Description attachment
None

Processing Activity 1: Photos to Mesh

Software
InVesalius
Description
created .ply file using a manual threshold

Processing Activity 2:

Software
Meshlab
Description
added landmarks, removed background

Media produced by this event on MorphoSource

Media 000418324: Pelvis [Mesh] [CT] (this media)