Media 000429874: Shell
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000429874: Shell
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000429874
Media type
Mesh
Object element or part
shell
Object represented
Object taxonomy
Pecten maximus
Object organization
Side
Right
Orientation
--
Short description
Right valve of shell
Full description
--
Creator
Katie Collins
Date created
August 10, 2017
Date uploaded
March 09, 2022
FILE OBJECT DETAILS Field Definitions
File name
1566.stl
File format(s)
STL
File size
36.8 MB
Points
385395
Polygons
770832
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
36.498, 157.523, 140.387
Centroid coordinates
-43.622, -4.332, 0.629
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
fmnh:invertebrate zoology:25529
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Collins, Katie S.
Event date
August 10, 2017
Software
--
Description
X Pixel Spacing= 105.897 µm , Y Pixel Spacing= 105.897 µm , Z Pixel Spacing= 105.897 µm
Description Attachment
None
Photographic Reference
None
Filter
0.1mm Cu
Exposure time
131 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
2000
Voltage
200
Power
42
Amperage
200
Surrounding material
--
X-ray tube type
240kv
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
105.897
Detector pixels Y
--
Detector pixels size Y
105.897
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000429874: Shell [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Katie Collins
Event date
--
Software
VG StudioMax
Description
--
Description attachment
None