Media 000429888: Shell
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000429888
Media type
Mesh
Object element or part
shell
Object represented
Object taxonomy
Pholas dactylus
Side
Left
Orientation
--
Short description
left valve of shell
Full description
--
Creator
Stewart Edie
Date created
December 14, 2020
Date uploaded
March 09, 2022

FILE OBJECT DETAILS Field Definitions

File name
2380.stl
File format(s)
STL
File size
16 MB
Points
168002
Polygons
336206
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
21.557, 28.313, 91.925
Centroid coordinates
30.875, 7.115, 4.285
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:IZ:USNM 337277 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Katie Collins
Event date
December 14, 2020
Software
VG StudioMax
Description
X Pixel Spacing= 65 µm , Y Pixel Spacing= 65 µm , Z Pixel Spacing= 65 µm
Description Attachment
None
Photographic Reference
None
Filter
0.1mm Cu
Exposure time
0.131
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2000
Voltage
190
Power
36.1
Amperage
190
Surrounding material
plastic, foam
X-ray tube type
240 kV
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
65
Detector pixels Y
--
Detector pixels size Y
65
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000429888: Shell [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Stewart Edie
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000429888: Shell [Mesh] [CT] (this media)