Media 000430724: Peripheral Iv, Nmb Chc.270
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000430724
Media type
Mesh
Object element or part
Peripheral IV, NMB CHC.270
Object taxonomy
Chelydropsis aubasi
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Yann Rollot
Date created
March 14, 2022
Date uploaded
March 14, 2022

FILE OBJECT DETAILS Field Definitions

File name
Peripheral_IV_right_CHC270.ply
File format(s)
PLY
File size
16.9 MB
Points
240544
Polygons
484457
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
30571.602, 33854.500, 37870.200
Centroid coordinates
61685.603, 38733.105, 27233.431
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211, CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
Creator
Walter Joyce
Event date
February 25, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
90
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
180
Power
--
Amperage
35
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
1920
Detector pixels size X
0.045
Detector pixels Y
1536
Detector pixels size Y
0.045
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000430683: Carapace, Peripherals [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Walter Joyce
Event date
February 25, 2021
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000430683: Carapace, Peripherals [CTImageSeries] [CT] was processed to create derived Media 000430724: Peripheral Iv, Nmb Chc.270 [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Yann Rollot
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000430724: Peripheral Iv, Nmb Chc.270 [Mesh] [CT] (this media)