Media 000434905: Whole Specimen
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000434905
Media type
Volumetric Image Series
Object element or part
Whole specimen
Object represented
Object taxonomy
Acanthonus armatus
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
March 15, 2022
Date uploaded
April 12, 2022

FILE OBJECT DETAILS Field Definitions

File name
Acanthonus_armatus_UF_180163.zip
File format(s)
ZIP archive, DICOM
File size
242 MB
Image width
1200
Image height
1200
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.054959
Y pixel spacing
0.054959
Z pixel spacing
54.959000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,024

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m, Micro-Computed Tomography Imaging Center (mCTIC) (National Museum of Natural History, Smithsonian Institution)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Fish:180163 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Micro-Computed Tomography Imaging Center (mCTIC) (National Museum of Natural History, Smithsonian Institution)
Creator
--
Event date
March 15, 2022
Software
--
Description
Whole specimen
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
250 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
60 kV
Power
--
Amperage
400 uA
Surrounding material
Plastic bag
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000434905: Whole Specimen [CTImageSeries] [CT] (this media)