Media 000435545: Dissected Chondrocranium (Right Half)
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000435545: Dissected Chondrocranium (Right Half)
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000435545
Media type
Volumetric Image Series
Object element or part
Dissected chondrocranium (right half)
Object represented
Object taxonomy
Squalus acanthias
Object organization
Side
Right
Orientation
--
Short description
Dissected right half of chondrocranium
Full description
This scan is the right half of a dissected chondrocranium (it had to be cut in half to fit in the micro CT scanner). Most of the skin has been removed but much of the remaining soft tissue has been left in place. There was preexisting damage to the rostrum of the dissection specimen.
Creator
3D Anatomy Studios
Date created
April 11, 2022
Date uploaded
April 15, 2022
FILE OBJECT DETAILS Field Definitions
File name
shark_chondrocranium_26um_1k_Rec.zip
File format(s)
ZIP archive, BMP
File size
3.68 GB
Image width
2000
Image height
2000
Color space
--
Color depth
8
Compression
0; None; BI_RGB
Series type
Reconstructed image stack
X pixel spacing
26.131590
Y pixel spacing
26.131590
Z pixel spacing
26.131590
Pixel spacing units
Um
Slice thickness
26.13159
Number of images in set
4,694
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1276, Keck XROMM Core Facility (Brown University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
3D Anatomy Studios
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
We thank the Keck XROMM Core Facility (Brown University) for their donation of scanning time.
Publisher
3D Anatomy Studios
Cite as
3D Anatomy Studios (2022). CT scan of a spiny dogfish shark (Squalus acanthias) purchased from Carolina Biological Supply, ID 3DAS-ID00003 (published BMP files). Retrieved from MorphoSource ARK: [Insert ARK link].
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
3DAS:00003
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Keck XROMM Core Facility (Brown University)
Creator
3D Anatomy Studios
Event date
April 11, 2022
Software
Skyscan v1.5
Description
--
Description Attachment
None
Photographic Reference
None
Filter
Al 0.25mm
Exposure time
230
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
OFF (2)
Projections
--
Voltage
80
Power
--
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000435545: Dissected Chondrocranium (Right Half) [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
3D Anatomy Studios
Event date
April 11, 2022
Software
--
Description
--
Description attachment
None