Media 000440663: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000440663
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Canis lupus familiaris
Object organization
Side
--
Orientation
Vertical
Short description
--
Full description
Breed: Saluki
Creator
--
Date created
March 21, 2022
Date uploaded
May 10, 2022

FILE OBJECT DETAILS Field Definitions

File name
LACM22825_Dicom.zip
File format(s)
ZIP archive, DICOM
File size
2.73 GB
Image width
998
Image height
1060
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.109497
Y pixel spacing
0.109497
Z pixel spacing
0.109497
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,000

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Molecular Imaging Center (University of Southern California)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
This imaging was funded by ONR award N00014-21-1-2347
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object LACM:Mammals:22825 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Molecular Imaging Center (University of Southern California)
Creator
--
Event date
March 10, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1440
Voltage
80
Power
--
Amperage
120
Surrounding material
--
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
2000
Detector pixels size X
200
Detector pixels Y
2000
Detector pixels size Y
200
Detector configuration
--
Source object distance
610.793663024902
Source detector distance
1115.631
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000432235: Skull [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
March 10, 2022
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000432235: Skull [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000440663: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
Reconstructed Slices
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

Media 000440663: Skull [CTImageSeries] [CT] (this media)