Media 000440974: Holotype
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000440974
Media type
Volumetric Image Series
Object element or part
Holotype
Object represented
Object taxonomy
Brachydegma caelatum
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Friedman, Matt; Argyriou, Thodoris
Date created
--
Date uploaded
May 11, 2022

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
27.7 GB
Image width
2000
Image height
2000
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Projections
X pixel spacing
0.048424
Y pixel spacing
0.048424
Z pixel spacing
0.048424
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
4,294

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:VP:VPF-6503 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
Argyriou, Thodoris; Friedman, Matt
Event date
--
Software
--
Description
microCT projections for MCZ_VPF_6503
Description attachment
None
Reference attachment
None
Filter
Copper 1.25 mm
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
269.757648468018
Source detector distance
1114.153
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000440974: Holotype [CTImageSeries] [CT] (this media)