Media 000442037: Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000442037: Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000442037
Media type
Volumetric Image Series
Object element or part
Body
Object represented
Object taxonomy
Auchenipterichthys thoracatus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Randall, Zach
Date created
May 12, 2022
Date uploaded
May 12, 2022
FILE OBJECT DETAILS Field Definitions
File name
CUMV_Fish_88997.zip
File format(s)
ZIP archive, TIFF
File size
1010 MB
Image width
483
Image height
687
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.065637
Y pixel spacing
0.065637
Z pixel spacing
0.065637
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,022
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
CUMV:Fish:88997
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Randall, Zach
Event date
February 21, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
200.098
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
960
Voltage
80
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000442037: Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Randall, Zach
Event date
May 12, 2022
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000442037: Body [CTImageSeries] [CT] (this media)