Media 000445238: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview disabled by data contributor.

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000445238
Media type
Volumetric Image Series
Object element or part
--
Object taxonomy
Actinopterygii indet.
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Bronson, Allison
Date created
June 09, 2021
Date uploaded
May 31, 2022

FILE OBJECT DETAILS Field Definitions

File name
z_substack_whole_fish.zip
File format(s)
ZIP archive, TIFF
File size
1.04 GB
Image width
546
Image height
489
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.039377
Y pixel spacing
0.039377
Z pixel spacing
0.039377
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,495

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon XT H 225, Department of Biological Sciences (Humboldt State University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Scripps Institution of Oceanography
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Thumbnail Only
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object sio:marine vertebrates:20-41 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Department of Biological Sciences (Humboldt State University)
Creator
Bronson, Allison
Event date
June 09, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
500 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
4476
Voltage
100
Power
--
Amperage
65
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2850
Detector pixels size X
0.15
Detector pixels Y
2850
Detector pixels size Y
0.15
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000445238: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Bronson, Allison
Event date
June 09, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000445238: Element Unspecified [CTImageSeries] [CT] (this media)