Media 000446399: Humerus
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000446399
Media type
Volumetric Image Series
Object element or part
Humerus
Object represented
Object taxonomy
Uropsilus gracilis
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
June 13, 2022

FILE OBJECT DETAILS Field Definitions

File name
Uropsilus_gracilis-AL1305058-hum-ImJreor.zip
File format(s)
ZIP archive, TIFF
File size
1.23 GB
Image width
780
Image height
690
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
4.700000
Y pixel spacing
4.700000
Z pixel spacing
4.700000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
1,701

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker Skyscan 1272, Staatliches Museum für Naturkunde Stuttgart (Staatliches Museum für Naturkunde Stuttgart)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object kiz:AL1305058 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Staatliches Museum für Naturkunde Stuttgart (Staatliches Museum für Naturkunde Stuttgart)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000446399: Humerus [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
NRecon
Description

Processing Activity 2: Crop

Software
Fiji
Description
Cropped and reoriented

Media produced by this event on MorphoSource

Media 000446399: Humerus [CTImageSeries] [CT] (this media)