Media 000451810: Carapace
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000451810: Carapace
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000451810
Media type
Mesh
Object element or part
Carapace
Object represented
Object taxonomy
Glyptemys insculpta
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Guilherme Hermanson
Date created
July 25, 2022
Date uploaded
July 25, 2022
FILE OBJECT DETAILS Field Definitions
File name
Glyptemys_insculpta_YPM-VZ5947_Carapace.ply
File format(s)
PLY
File size
300 MB
Points
7170247
Polygons
14308050
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
100.266, 138.869, 57.736
Centroid coordinates
60.914, 82.245, 51.775
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
YPM:VZ:YPM HERR 005947
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2000
Voltage
120
Power
0.024
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000072843: Whole Body [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000072843: Whole Body [CTImageSeries] [Etc]
was processed
to create
derived
Media 000451810: Carapace [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Guilherme Hermanson
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000451810: Carapace [Mesh] [CT] (this media)