Media 000455690: Stl Filled
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents cultural heritage object
Managed by

Media Display

In Collections

GENERAL DETAILS Field Definitions

Media ID
000455690
Media type
Mesh
Object element or part
STL Filled
Side
--
Orientation
--
Short description
(STL) MicroCT of Bird Effigy Whistling Pot
Full description
--
Creator
Claxton, Alex
Date created
March 09, 2021
Date uploaded
August 11, 2022

FILE OBJECT DETAILS Field Definitions

File name
BirdWhistlePot_Filled.stl
File format(s)
STL
File size
561 MB
Points
5880490
Polygons
11760648
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1047.548, 1518.265, 1683.704
Centroid coordinates
590.370, 831.608, 616.301
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
2
Number of processing events
3 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, MICRO - MicroCT Imaging Consortium for Research and Outreach (University of Arkansas)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
University of Arkansas Museum
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 2012590
Publisher
MICRO/University of Arkansas Museum
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uam:94-13-2 Bird Effigy Whistling Pot was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
MICRO - MicroCT Imaging Consortium for Research and Outreach (University of Arkansas)
Creator
Manon Wilson
Event date
March 09, 2021
Software
Inspect X
Description
--
Description attachment
None
Reference attachment
None
Filter
Copper 0.5 mm
Exposure time
708
Flux normalization
No
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
4
Projections
3141
Voltage
212
Power
111.94
Amperage
528
Surrounding material
Styrofoam
X-ray tube type
225 kV X-ray tube with a fixed tungsten reflection target.
Target type
Reflection
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungsten
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000455558: 16 Bit [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Manon Wilson
Event date
March 09, 2021
Software
CT 3D Pro
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Processing Details Field Definitions

Creator
Manon Wilson
Event date
March 09, 2021
Software
CT 3D Pro
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 4: IMAGE PROCESSING

Derived Media 000455585: 8 Bit [CTImageSeries] [CT] was processed to create derived Media 000455690: Stl Filled [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Manon Wilson
Event date
March 09, 2021
Software
CT 3D Pro
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000455690: Stl Filled [Mesh] [CT] (this media)