Media 000456240: Metadata
Open Download
Type Other
Modality X-Ray Computed Tomography (CT/microCT)
Media represents cultural heritage object
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
· Public

GENERAL DETAILS Field Definitions

Media ID
000456240
Media type
Other
Object element or part
Metadata
Object represented
Side
--
Orientation
--
Short description
(Metadata) MicroCT of Ceramic Sherd
Full description
--
Creator
Manon Wilson
Date created
June 18, 2020
Date uploaded
August 12, 2022

FILE OBJECT DETAILS Field Definitions

File name
CeramicSherd_Metadata.zip
File format(s)
ZIP archive, text/xml
File size
36.4 KB

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, MICRO - MicroCT Imaging Consortium for Research and Outreach (University of Arkansas)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
MICRO
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 2012590
Publisher
MICRO
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object Ceramic Sherd was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
MICRO - MicroCT Imaging Consortium for Research and Outreach (University of Arkansas)
Creator
Manon Wilson
Event date
June 18, 2020
Software
Inspect X
Description
--
Description attachment
None
Reference attachment
None
Filter
Copper 0.125
Exposure time
708
Flux normalization
No
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
2
Projections
3141
Voltage
191
Power
23.49
Amperage
123
Surrounding material
Styrofoam
X-ray tube type
225 kV X-ray tube with a rotating tungsten reflection target.
Target type
Reflection
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungsten
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000455884: 16 Bit [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Manon Wilson
Event date
June 18, 2020
Software
CT 3D Pro
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000455884: 16 Bit [CTImageSeries] [CT] was processed to create derived Media 000456240: Metadata [Other] [CT] (this media).

Processing Details Field Definitions

Creator
Manon Wilson
Event date
June 18, 2020
Software
CT 3D Pro
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000456240: Metadata [Other] [CT] (this media)