Media 000456718: Dice Ct
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000456718
Media type
Volumetric Image Series
Object element or part
diceCT
Object represented
Object taxonomy
Xenopeltis unicolor
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Record created by batch submission.
Creator
Edward Stanley
Date created
--
Date uploaded
August 13, 2022

FILE OBJECT DETAILS Field Definitions

File name
UF-herp-191595-diceCT-body.zip
File format(s)
ZIP archive, TIFF
File size
3.35 GB
Image width
1261
Image height
1848
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.082325
Y pixel spacing
0.082325
Z pixel spacing
0.082325
Pixel spacing units
Mm
Slice thickness
0.08232521
Number of images in set
2,049

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:herp:191595 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
333.096
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
2200
Voltage
180
Power
0.036
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2024
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
330.44325
Source detector distance
802.77534791
Target material
tungston
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000456718: Dice Ct [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
DatosX|R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000456718: Dice Ct [CTImageSeries] [CT] (this media)