Media 000457230: Cranium
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000457230: Cranium
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000457230
Media type
Volumetric Image Series
Object element or part
cranium
Object represented
Object taxonomy
Ptilocercus lowii
Object organization
Side
Midline
Orientation
--
Short description
cranium - post orbital bars broken
Full description
cranium - post orbital bars broken: fragments scanned with cranium in gel cap. tip of lower jaw also appears in scan.
Creator
Doug Boyer; April Neander
Date created
August 19, 2022
Date uploaded
August 19, 2022
FILE OBJECT DETAILS Field Definitions
File name
FMNH76855_cranium.zip
File format(s)
ZIP archive, TIFF
File size
13.7 GB
Image width
1629
Image height
1668
Color space
BlackIsZero
Color depth
16
Compression
LZW
Series type
Reconstructed image stack
X pixel spacing
0.012047
Y pixel spacing
0.012047
Z pixel spacing
0.012047
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,276
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Mammals:76855
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Neander
Event date
April 20, 2017
Software
VG StudioMax
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2024
Detector pixels size X
0.20000000
Detector pixels Y
2024
Detector pixels size Y
0.20000000
Detector configuration
Area (single or tiled detector)
Source object distance
56.57643750
Source detector distance
939.22555878
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 2 activities
to create
derived
Media 000457230: Cranium [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Doug Boyer, April Neander
Event date
August 19, 2022
Software
Avizo; VG Studio Max
Description
Scan created by April. Scan cropped and uploaded by Doug
Description attachment
None
Processing Activity 1: Reconstruction
Software
VG Studio Max
Description
Done by PaleoCT lab in 2017
Processing Activity 2: Crop
Software
Avizo
Description
Done at Boyer Lab
Media produced by this event on MorphoSource
Media 000457230: Cranium [CTImageSeries] [CT] (this media)