Media 000474337: Endocast And Semicircular Canals
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000474337: Endocast And Semicircular Canals
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000474337
Media type
Mesh
Object element or part
Endocast and semicircular canals
Object represented
Object taxonomy
Plesiobaena sp.
Object organization
Side
--
Orientation
--
Short description
--
Full description
3D volume rendering of digital endocast and semicircular canals of BDM 004
Creator
Heather F. Smith
Date created
September 14, 2022
Date uploaded
October 14, 2022
FILE OBJECT DETAILS Field Definitions
File name
BDM_004_Endocast_SSC.ply
File format(s)
PLY
File size
320 MB
Points
4468474
Polygons
8949620
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
631.146, 882.921, 1605.647
Centroid coordinates
1110.848, 1040.291, 1032.303
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
1
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
ZEISS Xradia 520 Versa, Chawla Research Group (Purdue University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Heather F. Smith
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Midwestern University Core Facility Funds
Publisher
Heather F. Smith
Cite as
Heather F. Smith provided access to these data originally appearing in …. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
BDM:BDM:BDM 004
was imaged to create
raw
Media 000474320: Cranium [CTImageSeries] [CT].
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Chawla Research Group (Purdue University)
Creator
Heather Smith
Event date
March 05, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
10.000000
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2026
Voltage
120 V
Power
--
Amperage
84.000000
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
29.214855
Detector pixels Y
--
Detector pixels size Y
29.214855
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
Yes
Acquisition type
--
Media produced by this event on MorphoSource
STEP 2: IMAGE PROCESSING
Raw
Media 000474320: Cranium [CTImageSeries] [CT]
was processed
to create
derived
Media 000474337: Endocast And Semicircular Canals [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Heather F. Smith
Event date
September 14, 2022
Software
Aviso
Description
Endocast and semicircular canals
Description attachment
None
Media produced by this event on MorphoSource
Media 000474337: Endocast And Semicircular Canals [Mesh] [CT] (this media)