Media 000475857: Silica Concretion 107
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000475857
Media type
Mesh
Object element or part
silica concretion 107
Object represented
Object taxonomy
Brooksella alternata
Side
--
Orientation
--
Short description
stl of moderate resolution mask of uct imaged silica concretion
Full description
stl reconstructed from mask of uct scan of a Weiss lake silica concretion
Creator
Nolan, Morrison
Date created
October 05, 2022
Date uploaded
October 19, 2022

FILE OBJECT DETAILS Field Definitions

File name
Concretion_107.stl
File format(s)
STL
File size
416 MB
Points
1108960
Polygons
2216988
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
7.571, 4.453, 9.729
Centroid coordinates
5.101, 5.107, 5.178
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 510 Versa x-ray microscope (xrm), University of Missouri X-ray Microanalysis Core (University of Missouri)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
University of Missouri X-ray Microanalysis Core (University of Missouri)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
2-7 seconds
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
80 kV
Power
7 W
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
Yes
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw Media 000472006: Isolated Nodule Of Silica Concretion 107 [CTImageSeries] [CT] was processed to create derived Media 000475857: Silica Concretion 107 [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Nolan, Morrison
Event date
October 05, 2022
Software
Mimics
Description
stl of silica concretion 107
Description attachment
None

Media produced by this event on MorphoSource

Media 000475857: Silica Concretion 107 [Mesh] [CT] (this media)