Media 000476294: Forelimb
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000476294: Forelimb
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000476294
Media type
Mesh
Object element or part
Forelimb
Object represented
Object taxonomy
Desmodus rotundus
Object organization
Side
Right
Orientation
--
Short description
Repositioned wing with bone elements colored
Full description
Skeleton of the right wing of a common vampire bat, Desmodus rotundus (Specimen UF M9818), a fluid-preserved specimen from the Florida Museum of Natural History, with elements colored to demonstrate forelimb anatomy. This scene was created by Jaimi Gray (oVert team) using pre-existing mesh files (see below) which were edited to separate, reposition, and color elements in Blender and Meshlab.
Original segmentation and mesh files by Karina Riddell using Volumegraphics VGStudioMax 3.3 from a CT scan produced by a Phoenix V|Tome|X S. The model was generated to complement a learning activity designed during the UF Center for Precollegiate Education and Training workshop “3D Vertebrates: From Museum Shelves to Classrooms.” Scanning and modeling of this specimen was funded by the oVert project at the University of Florida (NSF DBI 1701714, https://tinyurl.com/oVertwiki).
Creator
Jaimi Gray
Date created
October 20, 2022
Date uploaded
October 20, 2022
FILE OBJECT DETAILS Field Definitions
File name
Vampire-bar-UF-mamm-9818.ply
File format(s)
PLY
File size
12.6 MB
Points
213505
Polygons
427991
Map type
--
UV coordinates
True
Vertex color
True
Bounding box dimensions
33.597, 173.911, 86.809
Centroid coordinates
1.448, 0.435, 2.682
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Mammals:9818
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000445804: Whole Body [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
July 13, 2018
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000445804: Whole Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000476294: Forelimb [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Jaimi Gray
Event date
October 20, 2022
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000476294: Forelimb [Mesh] [CT] (this media)