Media 000481482: Mandible
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000481482
Media type
Mesh
Object element or part
Mandible
Object represented
Object taxonomy
Plesiadapis cookei
Object organization
Side
--
Orientation
--
Short description
Mandible with both incisors and other teeth
Full description
--
Creator
Tajaun Gibbison
Date created
November 09, 2022
Date uploaded
November 09, 2022

FILE OBJECT DETAILS Field Definitions

File name
Boyer_UMMP_65720_Plesiadapis_cookei_mesh.ply
File format(s)
PLY
File size
35.9 MB
Points
499894
Polygons
999813
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
56.340, 36.797, 42.735
Centroid coordinates
29.825, 25.961, 19.775
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummp:vp:65720 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
2000
Voltage
130
Power
--
Amperage
110
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000481439: Mandible [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Tajaun Gibbison
Event date
--
Software
Avizo
Description
--
Description attachment
None

Processing Activity 1: Transform: Reflection

Software
Avizo
Description

Processing Activity 2: Crop

Software
Avizo
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000481439: Mandible [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000481482: Mandible [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Tajaun Gibbison
Event date
--
Software
Avizo
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000481482: Mandible [Mesh] [CT] (this media)