Media 000485363: Shell Valve
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000485363: Shell Valve
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000485363
Media type
Mesh
Object element or part
shell valve
Object represented
Object taxonomy
Glorichlamys quadrilirata
Object organization
Side
Left
Orientation
--
Short description
--
Full description
Record created by batch submission.
Creator
Katie Collins
Date created
--
Date uploaded
November 29, 2022
FILE OBJECT DETAILS Field Definitions
File name
1504.stl
File format(s)
STL
File size
8.07 MB
Points
84629
Polygons
169254
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.099, 19.717, 15.134
Centroid coordinates
22.810, 2.698, -1.716
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution; National Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
usnm:invertebrate zoology:763697
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
--
Event date
--
Software
Phoenix Datos|x
Description
--
Description Attachment
None
Photographic Reference
None
Filter
0.1mm Cu
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
0
Projections
2000
Voltage
150
Power
30
Amperage
200
Surrounding material
--
X-ray tube type
240 kV
Target type
Reflection
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000485363: Shell Valve [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Katie Collins
Event date
--
Software
VG StudioMax
Description
--
Description attachment
None