Media 000491975: Basicranium Iwcms 2014.95.3
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000491975: Basicranium Iwcms 2014.95.3
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000491975
Media type
Volumetric Image Series
Object element or part
Basicranium IWCMS 2014.95.3
Object represented
Object taxonomy
Ceratosuchops inferodios
Object organization
Side
--
Orientation
--
Short description
Bascranium elements of Ceratosuchops inferodios (IWCMS 2019.95.3)
Full description
--
Creator
Barker, Chris
Date created
January 16, 2023
Date uploaded
January 16, 2023
FILE OBJECT DETAILS Field Definitions
File name
Basicranium_Image_Sequence_mod.zip
File format(s)
ZIP archive, TIFF
File size
1.73 GB
Image width
2000
Image height
2000
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.109745
Y pixel spacing
0.109745
Z pixel spacing
0.109745
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,729
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom 225/450kV Walk In Micro focus, µ-VIS X-ray Imaging Centre (University of Southampton)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Southampton
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Institute for Life Sciences (University of Southampton); EPSRC (grant no. 2283360)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
miwg:IWCMS 2014.95
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
µ-VIS X-ray Imaging Centre (University of Southampton)
Creator
Rankin, Katy
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250ms
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
16
Projections
3142
Voltage
300kV
Power
--
Amperage
250uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000491975: Basicranium Iwcms 2014.95.3 [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Barker, Chris
Event date
--
Software
FIJI
Description
Concatenation of CT data
Description attachment
None
Media produced by this event on MorphoSource
Media 000491975: Basicranium Iwcms 2014.95.3 [CTImageSeries] [CT] (this media)