Media 000492588: Hemi Mandible
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000492588
Media type
Volumetric Image Series
Object element or part
hemi-mandible
Object represented
Object taxonomy
Qarunavus meyeri
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Ferreira, Gabriel
Date created
January 26, 2022
Date uploaded
January 18, 2023

FILE OBJECT DETAILS Field Definitions

File name
SMNS-44287-Qarunavus.zip
File format(s)
ZIP archive, TIFF
File size
257 MB
Image width
646
Image height
2936
Color space
BlackIsZero
Color depth
8
Compression
LZW
X pixel spacing
0.039894
Y pixel spacing
0.039894
Z pixel spacing
0.039894
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,363

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon HT X 320, 3D Imaging Lab - 3DImg (Eberhard Karls Universität Tübingen/Geowissenschaften Fachbereich)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smns:p:44287 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
3D Imaging Lab - 3DImg (Eberhard Karls Universität Tübingen/Geowissenschaften Fachbereich)
Creator
Ferreira, Gabriel
Event date
January 26, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3500
Voltage
170 kV
Power
26.4 W
Amperage
155 µA
Surrounding material
--
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
0.039894
Detector pixels Y
--
Detector pixels size Y
0.039894
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Tungsten
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000492588: Hemi Mandible [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Ferreira, Gabriel
Event date
January 26, 2022
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000492588: Hemi Mandible [CTImageSeries] [CT] (this media)