Media 000500703: Head Dicect
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000500703: Head Dicect
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000500703
Media type
Volumetric Image Series
Object element or part
Head DICECT
Object represented
Object taxonomy
Nerodia sipedon
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Jaimi Gray
Date created
--
Date uploaded
March 03, 2023
FILE OBJECT DETAILS Field Definitions
File name
UF-herp-177819-DICECT_head.zip
File format(s)
ZIP archive, TIFF
File size
836 MB
Image width
896
Image height
594
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.022148
Y pixel spacing
0.022148
Z pixel spacing
0.022148
Pixel spacing units
Mm
Slice thickness
0.02214813
Number of images in set
2,272
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF:1701714
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:177819
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Event date
--
Software
Datos X|A
Description
DICECT scan of UF-herp-177819
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2100
Voltage
120
Power
24
Amperage
200
Surrounding material
air
X-ray tube type
240kv
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2014
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
88.8998750
Source detector distance
802.77534791
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000500703: Head Dicect [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Jaimi Gray
Event date
--
Software
Datos X|r
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000500703: Head Dicect [CTImageSeries] [CT] (this media)