Media 000501187: Whole Frog In Ethanol
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

GENERAL DETAILS Field Definitions

Media ID
000501187
Media type
Volumetric Image Series
Object element or part
Whole frog in Ethanol
Object represented
Object taxonomy
Scaphiophryne sp.
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Mark D. Scherz
Date created
July 26, 2019
Date uploaded
March 07, 2023

FILE OBJECT DETAILS Field Definitions

File name
Scaphiophryne-longimanus_MNHN1929-237_DICOM.zip
File format(s)
ZIP archive, TIFF
File size
11.7 GB
Image width
3072
Image height
2400
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.013618
Y pixel spacing
0.013618
Z pixel spacing
0.013618
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,441

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m, SNSB X-ray facility (Zoologische Staatssammlung München (Bavarian State Collection of Zoology))

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Mark D. Scherz
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
--
Publisher
Alice Petzold
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MNHN:RA:1929.237 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
SNSB X-ray facility (Zoologische Staatssammlung München (Bavarian State Collection of Zoology))
Creator
Mark D. Scherz
Event date
July 26, 2019
Software
MeVisLab; phoenix x reconstruct; VGStudio
Description
Whole frog in Ethanol
Description attachment
None
Reference attachment
None
Exposure time
750
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1440
Voltage
140
Power
--
Amperage
80
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Molyb
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
--

Media produced by this event on MorphoSource

Media 000501187: Whole Frog In Ethanol [CTImageSeries] [CT] (this media)