Media 000508920: Quadrate
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000508920
Media type
Mesh
Object element or part
Quadrate
Object represented
Object taxonomy
Colinus virginianus virginianus
Side
Right
Orientation
--
Short description
Complete right quadrate
Full description
--
Creator
Kuo, Pei-Chen
Date created
March 29, 2023
Date uploaded
March 29, 2023

FILE OBJECT DETAILS Field Definitions

File name
Colinus_virginianus_FMNH_105065_Quadrate.ply
File format(s)
PLY
File size
90.2 MB
Points
1418829
Polygons
491924
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.633, 6.724, 5.144
Centroid coordinates
8.079, 15.518, -12.726
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Birds:105065 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Neander
Event date
February 08, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
140
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000109722: Skeleton [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
April Neander
Event date
February 08, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000109722: Skeleton [CTImageSeries] [CT] was processed to create derived Media 000508920: Quadrate [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Kuo, Pei-Chen
Event date
March 29, 2023
Software
Avizo
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000508920: Quadrate [Mesh] [CT] (this media)